CCA Online Tools

๐Ÿ’ก Brightness

๐Ÿ“– CCA Handbook โ€บ Blueprint section: Brightness Configuration

Only for morning opening & evening closing!
This condition allows the cover to open earlier in the morning or close earlier in the evening,
triggered by ambient brightness reaching its threshold.
This is NOT related to sun protection / shading.

On this page: ๐Ÿ”… Default Brightness Sensor ยท ๐Ÿ”… Brightness Time Duration ยท ๐Ÿ”… Brightness Value For Opening The Cover ยท ๐Ÿ”… Brightness Value For Closing The Cover ยท ๐Ÿ”… Brightness Hysteresis Value


๐Ÿ”… Default Brightness Sensor

๐Ÿงฉ Input: default_brightness_sensor

This default brightness sensor can be defined here, which is used for daily up and down.


๐Ÿ”… Brightness Time Duration

๐Ÿงฉ Input: brightness_time_duration ยท Default: 30

Defines the time to given brightness sensor must be stay above/below the thresholds.


๐Ÿ”… Brightness Value For Opening The Cover

๐Ÿงฉ Input: brightness_up ยท Default: 0

At what brightness value should the cover be opened?


๐Ÿ”… Brightness Value For Closing The Cover

๐Ÿงฉ Input: brightness_down ยท Default: 0

At what brightness value should the cover be closed? Must be lower then the brightness up value.


๐Ÿ”… Brightness Hysteresis Value

๐Ÿงฉ Input: brightness_hysteresis ยท Default: 0

Cover will open only when brightness exceeds (brightness_up + hysteresis), and close only when it drops below (brightness_down - hysteresis). Prevents frequent open/close cycles.


โฌ…๏ธ Handbook index ยท Previous: โฐ Time & Calendar Control ยท Next: โ˜€๏ธ Sun Elevation